MALLINCKRODT INC. -- XYLENE -- 6810-00-584-4070
=====================  Product Identification  =====================

Product ID:XYLENE
MSDS Date:07/13/1987
FSC:6810
NIIN:00-584-4070
=== Responsible Party ===
Company Name:MALLINCKRODT INC.
Address:PARIS BYPASS
Box:M
City:PARIS
State:KY
ZIP:40361
Country:US
Info Phone Num:314-982-5000
Emergency Phone Num:314-982-5000
CAGE:62910
=== Contractor Identification ===
Company Name:MALLINCKRODT SPECIALTY CHEMICALS CO
Address:222 RED SCHOOL LANE
Box:City:PHILLIPSBURG
State:NJ
ZIP:08865
Country:US
Phone:908-859-2151
CAGE:62910

=============  Composition/Information on Ingredients  =============

Ingred Name:XYLENES (O-,M-,P- ISOMERS)	(SARA III)
CAS:1330-20-7
RTECS #:ZE2100000
OSHA PEL:100 PPM/150 STEL
ACGIH TLV:100 PPM/150STEL;9192
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:ORAL RAT:4300MG/KG
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Health Hazards Acute and Chronic:ACUTE:IRRITATION OF EYES,SKIN AND
    RESPIRATORY TRACT/CNS DEPRESSION,HEADACHE,NAUSEA,VOMITING,BREATHING
    DIFFICULTIES,COUGHING. CHRONIC:HEADACHE,LOSS
    APPETITE,DERMATITIS,EYE PROBLEM/CNS EFFECTS,LIVER OR  KIDNEY OR
    LUNGS PROBLEM.
Explanation of Carcinogenicity:NO DATA AVAILABLE.
Effects of Overexposure:SEE HEALTH HAZARDS DATA.
Medical Cond Aggravated by Exposure:PRE-EXISTING CONDITIONS MAY BE
    WORSEN,LIVER OR KIDNEY,RESPIRATORY PROBLEM.

=======================  First Aid Measures  =======================

First Aid:INHALATION:REMOVE TO FRESH AIR;CONSULT A PHYSICIAN. SKIN AND
    EYES:FLUSH WITH PLENTY OF WATER FOR ABOUT 15 MINUTES;SEEK MEDICAL
    HELP IF NEEDED. INGESTION:DO NOT INDUCE VOMITING;CALL A PHYSICIAN
    IMMEDIA TELY.

=====================  Fire Fighting Measures  =====================

Flash Point Method:TCC
Flash Point:79F/26.2C
Autoignition Temp:Autoignition Temp Text:867F
Lower Limits:1.0
Upper Limits:7.0
Extinguishing Media:DRY CHEMICAL,FOAM,CO*2.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA IN AN ENCLOSED
    AREA.
Unusual Fire/Explosion Hazard:ABOVE FLASH POINT,VAPOR AIR MIXTURE IS
    EXPLOSIVE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:USE PROPER PERSONAL PROTECTION;REMOVE ALL
    IGNITION SOURCES;CONTAIN FREE LIQUID;USE SUITABLE INERT ABSORBENT
    MATERIAL AND RECOVER FOR PROPER DISPOSAL.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN COOL,DRY AND WELL VENTLATED
    AREA;KEEP AWAY FROM HEAT,OPEN FLAMES;DONOT USE CONTAMINATED
    CLOTHES;KEEP CONTAINERS TIGHTLY CLOSED WHEN NOT IN US

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR FOR ORGANIC
    VAPORS/MIST IF ABOVE PEL/TLV.
Ventilation:LOCAL EXHAUST/GENERAL TO MAINTAIN PEL/TLV (USE EXPLOSION
    PROOF EQUIPMENT).
Protective Gloves:IMPERVIOUS.
Eye Protection:CHEMICAL SAFETY GOGGLES/FACE SHIELDS.
Other Protective Equipment:BOOTS,LAB COAT,APRON.EYE-WASH FOUNTAIN.
Work Hygienic Practices:AVOID CONTACT WITH EYES AND SKIN;DO NOT BREATHE
    VAPORS/MIST;DO NOT EAT,DRINK OR SMOKE IN WORK AREA.
Supplemental Safety and Health

==================  Physical/Chemical Properties  ==================

HCC:F2
Boiling Pt:B.P. Text:279F-284F
Melt/Freeze Pt:M.P/F.P Text:-13F/-25C
Vapor Pres:8.0
Vapor Density:3.7
Spec Gravity:0.86
Evaporation Rate & Reference:0.6 (BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR,COLORLESS LIQUID;CHARACTERISTIC ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:EXTREME HEAT;OPEN FLAME.
Hazardous Decomposition Products:CO AND UNIDENTIFIED ORGANIC COMPOUNDS.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF COLLECTED MATERIAL IN ACCORDANCE WITH
    LOCAL,STATE AND FEDERAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.