M GRUMBACHER INC -- TUFFILM FINAL FIXATIVE-GLOSS 543 -- 8010-00N051272
=====================  Product Identification  =====================

Product ID:TUFFILM FINAL FIXATIVE-GLOSS 543
MSDS Date:11/23/1992
FSC:8010
NIIN:00N051272
=== Responsible Party ===
Company Name:M GRUMBACHER INC
Address:30 ENGELHARD DR
City:CRANBURY
State:NJ
ZIP:08512
Country:US
Info Phone Num:609-655-8282
Emergency Phone Num:800-424-9300 (CHEMTREC)
CAGE:FO948
=== Contractor Identification ===
Company Name:GRUMBACHER M INC
Address:30 ENGELHARD DR
Box:City:CRANBURY
State:NJ
ZIP:08512
Country:US
Phone:609-655-8282
CAGE:72925
Company Name:M GRUMBACHER INC
Address:30 ENGELHARD DRIVE
City:CRANBURY
State:NJ
ZIP:08512
Phone:(609) 655-8282
CAGE:FO948

=============  Composition/Information on Ingredients  =============

Ingred Name:NO INGREDIENT FOR THIS FORMULATION_INGREDIENT

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE:MAY CAUSE DIZZ/NARCOSIS IN HIGH
    CONC. WILL CAUSE DEFAT OF SKIN. EFTS ARE REVERSIBLE. LONG TERM
    EXPOS (YEARS) TO HIGH CONC OF VAP MAY CAUSE LUNG, LIVER OR KIDNEY
    DAMAGE. THE SOLV LISTED HAVE BEEN  RPTD TO AFFECT  CNS. ASPIR HAZ
    IF SWALLOWED. EYE AND SKIN IRRIT. MAY IRRIT RESP TRACT. AVOID USING
    IF(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:PREGNANT/CONTEMPLATING PREGNANCY. MAY
    CAUSE HARM TO DEVELOPING FETUS. OVEREXPOS TO TOLUENE MAY CAUSE
    NASAL & BRAIN DAMAGE. TOLUENE APPEARS ON NAVY LISTING OF
    OCCUPATIONAL CHEM REPROD HAZ. SEE K CONSULTATION FROM APPROP HLTH
    PROFFESSIONAL CONCERNING LATEST HAZ LIST INFO & SAFE HNDLG & EXPOS
    INFO .
Medical Cond Aggravated by Exposure:HEART DISEASE. RESPIRATORY
    DISORDERS.

=======================  First Aid Measures  =======================

First Aid:EYES:FLUSH WITH COPIOUS AMOUNTS OF WATER FOR AT LEAST 15
    MINUTES . SKIN:FLUSH WITH SOAP AND WATER. CALL MD IMMEDIATELY .
    INHAL:REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE O*2/ARTIFICIAL R
    ESPIRATION . INGEST:DO NOT INDUCEVOMITING.

=====================  Fire Fighting Measures  =====================

Flash Point:-40F,-40C
Lower Limits:1.8
Upper Limits:12.0
Extinguishing Media:USE WATER FOG, DRY CHEMICAL OR CARBON DIOXIDE
Fire Fighting Procedures:NIOSH/MSHA APPROVED SCBA AND FULL PROTECTIVE
    EQUIPMENT . AEROSOL CANS MAY RUPTURE WHEN HEATED.
Unusual Fire/Explosion Hazard:HEATED CANS MAY BURST.

==================  Accidental Release Measures  ==================

Spill Release Procedures:USE ABSORBENT SWEEPING COMPOUND TO SOAK UP
    MATERIAL. PUT INTO CONTAINER. DISPOSE AS HAZARDOUS WASTE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:KEEP AWAY FROM HEAT, SPARKS, AND
    FLAME. STORE AT ROOM TEMPERATURES BELOW 120F.
Other Precautions:WHEN SPRAYING MORE THAN ONE HALF CAN CONTINUOUSLY OR
    MORE THAN ONE CAN CONSECUTIVELY, USE NIOSH/MSHA APPROVED
    RESPIRATOR.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:SELF CONTAINED BREATHING APPARATUS IF ABOVE TLV
    LIMIT EXCEEDING. NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
    EXPOSURE OF CONCERN .
Ventilation:LOCAL EXHAUST
Protective Gloves:NONE REQUIRED IF SPRAYING.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS.
Other Protective Equipment:CLOTHING OR EQUIPMENT.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:>-40F,>-40C
Vapor Density:4.0
Spec Gravity:0.8
Evaporation Rate & Reference:>1 (BUTYL ACETATE=1)
Solubility in Water:NIL
Appearance and Odor:CLEAR/SOLVENT ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
IMCOMPATIBLE WITH STRONG OXIDIZERS.
Stability Condition to Avoid:HIGH TEMPERATURES
Hazardous Decomposition Products:IN FIRE, WILL DECOMPOSE TO CARBON
    DIOXIDE, WATER.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH EPA RCRA, AND
    LOCAL, STATE, AND FEDERAL REGULATIONS .

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.