VULCAN MATERIALS COMPANY,CHEMICALS DIVISION -- TRICHLOROETHYLENE -- 6810-00N006895
=====================  Product Identification  =====================

Product ID:TRICHLOROETHYLENE
MSDS Date:01/01/1987
FSC:6810
NIIN:00N006895
=== Responsible Party ===
Company Name:VULCAN MATERIALS COMPANY,CHEMICALS DIVISION
Address:NO 1 METROPLEX DR
Box:7689
City:BIRMINGHAM
State:AL
ZIP:35253
Country:US
CAGE:1B637
=== Contractor Identification ===
Company Name:VULCAN MATERIALS CO
Address:NO 1 METROPLEX DR
Box:530390
City:BIRMINGHAM
State:AL
ZIP:35253
Country:US
Phone:316-524-5751
CAGE:1B637

=============  Composition/Information on Ingredients  =============

Ingred Name:TRICHLOROETHYLENE  (SARA III)
CAS:79-01-6
RTECS #:KX4550000
Fraction by Wt: 100%
OSHA PEL:100 PPM/100 STEL
ACGIH TLV:50 PPM/100,A5STEL;93
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS

=====================  Hazards Identification  =====================

Effects of Overexposure:INHAL:MAJOR EXPOS ROUTE;ACUTE EXPOS-NOSE,THROAT
    IRRIT,DRY,DRUNKEN,DROWSY,UNCONSCIOUS (SEE SUPP DATA)

=======================  First Aid Measures  =======================

First Aid:EYES,SKIN: REMOVE CONTAMINATED CLOTHING,FLUSH EXPOSED AREAS
    W/H*2O FOR AT LEAST 15 MIN. INHALATION: REMOVE TO FRESH AIR. IF
    BREATHING HAS STOPPED,ADMINISTER RESPIRATION OR O*2 IF AVAILABLE.
    INGESTION:	DONT INDUCE VOMITING. CALL PHYS & GET MED ATTN.

=====================  Fire Fighting Measures  =====================

Flash Point:NONE (TCC)
Lower Limits:8.0
Upper Limits:10.5
Extinguishing Media:CO*2,DRY CHEMICAL,FOAM
Fire Fighting Procedures:SCBA & FULL PROTECT CLOTHES SHOULD BE USED IN
    STORAGE AREAS.
Unusual Fire/Explosion Hazard:CONCENTRATED VAPS CAN BE IGNITED BY HIGH
    INTENSITY HEAT SOURCE. THERMAL DECOMP PRODUCES HCL,PHOSGENE

==================  Accidental Release Measures  ==================

Spill Release Procedures:EVACUATE THE AREA,VENTILATE,AVOID BREATHING
    VAPORS,CONTAIN SPILL. CLEAN UP AREA (WEAR PROTECTIVE CLOTHING) BY
    MOPPING OR W/ABSORBENT MATERIAL,TRANSFER TO CLOSED CONTAINER.SPILLS
    OVER 1000 LBS ARE REPO RTABLE UNDER 49 CFR PART 172.101.

======================	Handling and Storage  ======================

Handling and Storage Precautions:AVOID SKIN CONT & BREATHING VAPS.PIPE
    VENTS OUTDOORS.STORE IN COOL,DRY,VENT AREA.VAPS HEAVIER THAN
    AIR,COLLECT IN LOW AREA.PREV MOIST AIR FROM STORAGE
Other Precautions:NO SMOKING IN AREA OF USE. DONT USE NEAR ARC
    WELDING,OPEN FLAME,HOT SURFS. HEAT &/OR UV RADIATN MAY FORM HCL
    &/OR PHOSGENE. PROT GLOVES: NEOPRENE,VITON,POLYVINYL ALCOHOL COATED
    OR EQUIVALENT.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE REQUIRED WHEN USED W/ADEQUATE VENTILATION
Ventilation:SUFFICIENT TO MAINTAIN BELOW TLV
Protective Gloves:SEE OTHR PRECAU
Eye Protection:CHEMICAL SAFETY GOGGLES
Other Protective Equipment:PROT HEADGEAR,APRON WHEN SPLASH IS
    PROBLM.DONT WEAR CONTACTS
Supplemental Safety and Health
POSS DEATH.SKIN:POSS DERMATITIS W/PRLNG,RPTD CONTACT (DEFATS).SKIN
    ABSORPTN NOT MAJOR EXP ROUTE-MILD IRRIT.INGEST:UNLIKELY EXP
    ROUTE.MOD-LOW TOX,SEE INHAL.EYES:MILD IRRIT,POSS CONJUNCTIVITIS.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:188F
Vapor Pres:58
Vapor Density:4.5
Spec Gravity:1.5
Evaporation Rate & Reference:0.3 (ETHER)
Solubility in Water:SLIGHT
Appearance and Odor:COLORLESS CLEAR LIQUID;MILDLY SWEET ODOR
Percent Volatiles by Volume:100

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG ALKALIES,OXIDIZING MATERIALS
Stability Condition to Avoid:CONTACT W/OPEN FLAME,HOT SURFACES OR
    ELECTRIC ARCS
Hazardous Decomposition Products:DICHLOROACETYLENE,HYDROGEN
    CHLORIDE,PHOSGENE

====================  Disposal Considerations  ====================

Waste Disposal Methods:RECOVERED LIQUIDS MAY BE SENT TO A LICENSED
    RECLAIMER OR INCINERATED. CONTAMINATED ABSORBENT MATERIAL MUST BE
    DISPOSED OF IN A PERMITTED WASTE MANAGEMENT FACILITY. CONSULT
    FEDERAL,STATE OR LOCAL AUTHO RITIES FOR APPROVED PROCEDURES.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.